What Our Last 10SurveysFound.
Lincolnshire Damp & Mould Findings 2026. The facts on this page come from our own last 10 damp and mould surveys across Lincoln and Lincolnshire, July to November 2026: 6 mould reports and 4 full damp surveys. No national averages, no borrowed numbers.
The short version.
- 100%
of our last 10 surveys found condensation or poor ventilation contributing to the damp or mould.
10 of 10 · surveys - 63%
of homes had no working bathroom extractor fan: none fitted, or one that had failed.
5 of 8 · homes where recorded - 63%
of homes had no trickle vents in the windows at all. Not one had a full set fitted and open.
5 of 8 · homes where recorded - 30%
of properties had rising damp, and every one of them had another source of moisture as well.
3 of 10 · surveys
- 100%
of mould reports that blamed occupant habits also found the home short of ventilation.
5 of 5 · reports with a lifestyle factor - 100%
of homes with identifiable mould showed Cladosporium. Stachybotrys was found in none.
7 of 7 · homes with identifiable mould
What caused the damp and mould?
Each report ticks every cause that contributed, so the bars add up to more than 100%. That is the point: in our surveys damp and mould were almost never down to a single fault.
Mould reports
Share of 6 mould reports where each cause contributed
Show the numbers
| Finding | Count | Out of (mould reports) | Share |
|---|---|---|---|
| Inadequate ventilation | 6 | 6 | 100% |
| Condensation | 5 | 6 | 83% |
| Occupancy or lifestyle factors | 5 | 6 | 83% |
| Plumbing or internal leak | 1 | 6 | 17% |
Full damp surveys
Share of 4 damp surveys where each cause contributed
Show the numbers
| Finding | Count | Out of (damp surveys) | Share |
|---|---|---|---|
| Inadequate ventilation | 4 | 4 | 100% |
| Condensation | 3 | 4 | 75% |
| Penetrating damp | 3 | 4 | 75% |
| Damp proof course bridged or breached | 3 | 4 | 75% |
| Rising damp | 3 | 4 | 75% |
Rising damp was never the whole story
30% of the properties had rising damp. In 100% of those, another moisture source was working at the same time: penetrating damp through the walls, condensation, or both. A new damp proof course on its own would not have dried them out. That is why we survey before anyone quotes for injection. See rising damp in Lincoln.
Where the moisture had no way out.
From the room-by-room notes in each report. Each chart uses only the surveys that recorded that item.
Bathroom extractor fan
63% had no working fan · 8 homes where recorded
- Working
- Working but too weak
- Fan fitted but not working
- No fan fitted
Show the numbers
| Finding | Count | Out of (homes) | Share |
|---|---|---|---|
| Working | 1 | 8 | 13% |
| Working but too weak | 2 | 8 | 25% |
| Fan fitted but not working | 3 | 8 | 38% |
| No fan fitted | 2 | 8 | 25% |
Trickle vents in the windows
63% had none at all · 8 homes where recorded
- Fitted but shut or not working
- None fitted
Show the numbers
| Finding | Count | Out of (homes) | Share |
|---|---|---|---|
| Fitted and open | 0 | 8 | 0% |
| In some windows only | 0 | 8 | 0% |
| Fitted but shut or not working | 3 | 8 | 38% |
| None fitted | 5 | 8 | 63% |
Moisture from showers, cooking and drying clothes needs a way out. Without a working fan or open trickle vents it settles on the coldest surfaces. See how we approach condensation control.
How serious was it?
Mould severity
Worst level found · 6 mould reports
- No significant mould
- Minor
- Moderate
- Significant
Show the numbers
| Finding | Count | Out of (mould reports) | Share |
|---|---|---|---|
| No significant mould | 1 | 6 | 17% |
| Minor | 3 | 6 | 50% |
| Moderate | 1 | 6 | 17% |
| Significant | 1 | 6 | 17% |
HHSRS damp and mould rating
All 10 surveys
- Not a risk
- Category 2
- Category 1
Show the numbers
| Finding | Count | Out of (surveys) | Share |
|---|---|---|---|
| Not a risk | 8 | 10 | 80% |
| Category 2 | 1 | 10 | 10% |
| Category 1 | 1 | 10 | 10% |
30% needed major remedial work. A vulnerable occupant was flagged in 10%. Ratings follow the government's HHSRS operating guidance. Learn more about Awaab's Law and HHSRS surveys.
Which mould?
Where mould could be identified by eye, 100% of homes showed Cladosporium (7 of 7). Stachybotrys was found in none of our last 10 surveys. Identification is visual, not a laboratory test.
Where, and who asked.
By council district
Share of our last 10 surveys
Show the numbers
| Finding | Count | Out of (surveys) | Share |
|---|---|---|---|
| Lincoln | 4 | 10 | 40% |
| North Kesteven | 3 | 10 | 30% |
| East Lindsey | 1 | 10 | 10% |
| South Kesteven | 1 | 10 | 10% |
| West Lindsey | 1 | 10 | 10% |
Who commissioned the survey
Share of our last 10 surveys, from each report
Show the numbers
| Finding | Count | Out of (surveys) | Share |
|---|---|---|---|
| Homeowners | 5 | 10 | 50% |
| Buyers before purchase | 2 | 10 | 20% |
| Letting agents | 1 | 10 | 10% |
| Landlords | 1 | 10 | 10% |
| Not recorded | 1 | 10 | 10% |
Buying a house? See damp in period properties. Letting one? Damp and mould for landlords.
How we counted.
What is included. Our 10 most recent surveys, July to November 2026, out of 22 survey reports on file this year. The figures move to the latest 10 as each new report is issued.
How it was coded. Causes, mould severity, mould type, HHSRS rating and remedial level come from the summary tick boxes the surveyor completes on every report. Ventilation and external defects come from the room-by-room notes, and only count where the report records them. Percentages are rounded to the nearest whole number; the count behind each one is shown beside it.
The limits. Ten surveys is a small sample, and not a random one: people book a survey because they already suspect a problem. Mould type is identified by eye, not by laboratory testing. The data covers Lincolnshire and its borders only.
Sources. The HHSRS categories come from the government's operating guidance and landlord and agent guide. For Awaab's Law, see the GOV.UK guidance for social landlords.
Privacy. No addresses, names or exact dates are published. Each survey is shown by quarter and council district only.
Videos. The findings video is made from this data. The other clips are illustrations, not footage from our surveys.
Updated 13 November 2026.
Use this data.
Download the dataset
One row per survey, 10 rows, as a CSV file. Published under Creative Commons Attribution 4.0: free to use with credit.
Download CSVHow to cite it
The Damp & Mould Man (2026). Lincolnshire Damp & Mould Findings 2026. www.thedampandmouldman.co.uk/research/lincolnshire-damp-mould-findings
Journalists and researchers: for comment or the questions behind the numbers, see our press page.
What the data says.
In our last 10 surveys (July to November 2026), condensation or inadequate ventilation contributed in 100% (10 of 10), and in 100% of mould reports. The usual pattern was warm, moist air with no reliable way out, settling on the coldest surfaces such as window reveals, external corners and bathroom ceilings.
Rising damp was found in 30% of our last 10 surveys (3 of 10). In 100% of those cases another moisture source, such as penetrating damp or condensation, was present at the same time, so treating rising damp alone would not have fixed the problem.
Occupant habits, such as drying clothes indoors, were a contributing factor in 83% of our recent mould reports. In 100% of those the home was also short of ventilation, and in none was lifestyle the only cause recorded. In our data, mould is rarely down to one thing.
63% of the homes where we recorded it (5 of 8) had no working bathroom extractor fan: either none was fitted or the fitted one had failed. 63% had no trickle vents in the windows at all.
Where mould could be identified by eye, 100% of homes showed Cladosporium (7 of 7). Stachybotrys was found in none of our last 10 surveys. Visual identification is not a laboratory test, and we do not take air or swab samples.
Yes. The figures and the downloadable CSV are published under the Creative Commons Attribution 4.0 licence. Please credit The Damp & Mould Man and link to this page. No addresses or personal details are published.
Find out what is behind yours.
Mould report from £100+VAT, full damp survey from £250+VAT. Check your postcode and pick a slot from our diary. Not ready for a visit? Try remote damp and mould advice.
Book Online